DCM10 Reflectance Integrated SPO2 PPG Sensor

Facebook   Twitter   Delicious   Google   My EC21   Email this page   Report Item Inquire now
DCM10 Reflectance Integrated SPO2 PPG Sensor

Click to enlarge image

 Origin

Korea

 Model Number

DCM10

 Brand Name

APMK


The idea of using light reflection instead of light transmission in clinical oximetry shows that SpO2 can be monitored by measuring the amount of light reflected from the tissue. The idea of using skin reflectance spectrophotometry marked a significant advancement in the noninvasive monitoring of SpO2 from virtually any point on the skin surface.

The intensity of the back scattered light from the skin depends not only on the optical absorption spectrum of the blood but also on the structure and pigmentation of the skin. SpO2 is measured be analyzing the pulsatile componens of the detected red and infrared plethysmograms which make use of reflected light intensities. The light from the LEDs enters the tissue, is scattered by both the moving red blood cells and the nonmoving tissue, and a part of this back scattered light is detected by the photodiode.

The output of photodiode is processed by the pulse oximeter, and measures the SpO2 of the pulsatile blood. In reflectance pulse oximetry, the LEDs and the photodiode are placed on the same side of the skin surface as shown below. Normally the reflectance probe is placed on the forehead or temple, but is not restricted to only those two places. Reflectance probes can be used to measure arterial oxygen saturation at virtually any place the human body where the probe can be placed.

DCM10 developed by APMKorea is a sensor integrated built in LEDs and PD together with optimized properly against such trade-off to get proper parameters. Furthermore DCM10 has SMD type package so that user could interconnect easily wire or flip bonding into your set.

This reflectance sensor can be placed on the body where you can expect light reflection due to tissue.

Features

  • Small size 2 Emitters and Photo Detector
  • Chip on Board Package

Applications

  • Reflective PPG Probes
  • Wavelength Analysis on Skin
  • Wearable Medical Device

Absolute MAX. Ratings(Ta=25°C unless otherwise noted)

Symbol
Parameter
Max. Rated Value
Units
PD
Power Dissipation
120
mW
IF
Continuous Forward Current
50
mA
IFR
Peak Forward Current
100
mA
VR
Reverse Voltage
5
V
T stg
Storage Temp.
-20~+85
°C
T opr
Operating Temp.
-20~+85
°C
T sd
Soldering Temperature *1
240
°C
*1. Test Condition : t<3s

Characteristics(Ta=25°C unless otherwise noted)

PPG(Photo Plethysmogram) Characteristic



  Packaging

200pcs per pack

  Delivery lead time

1week